Heat Pump Size Calculator: What Size Do I Need? (2026)

In short: a heat pump size calculator gives you a first idea of the heating load of your home in BTU/h and the matching capacity in tons (1 ton = 12,000 BTU/h). In Quebec, a typical older home needs about 25 to 40 BTU/h per square foot at the coldest design temperature, while a recent, well-insulated house needs closer to 15 to 20. Use the tool below for an indicative estimate, then ask a contractor for a proper load calculation and compare up to 4 free quotes.

Get up to 4 free heat pump quotes

Describe your home in 2 minutes, no obligation.

Get my quotes →

Heat pump size calculator (Quebec and Ontario)

Enter your home details, then press Calculate.

What size heat pump do I need?

The right size is the one that matches the heat your home loses on the coldest days of a normal winter. That number is called the design heating load and it is expressed in BTU per hour. Heat pumps are sold in tons, a cooling unit inherited from air conditioning: one ton equals 12,000 BTU/h, so a “3-ton” unit is rated at about 36,000 BTU/h.

The catch in Quebec is that a heat pump’s nominal rating is measured in mild weather. As the outdoor temperature drops toward -20 °C and below, a standard unit delivers much less heat, while a cold-climate model holds a larger share of its capacity. That is why two homes with the same square footage can need very different equipment, and why the calculator shows a heating-based size and a cooling-based size side by side.

Heat pump BTU per square foot: rule-of-thumb table

The table below shows the typical heating load per square foot used in the calculator for the Montreal area. Colder regions add 4% to 16%; southern Ontario is a little lower. These are planning figures for a first budget, not engineering values.

House typeHeating load (BTU/h per sq ft)Example: 1,500 sq ft
Recent or high-performance house15 – 2023,000 – 30,000 BTU/h (2 to 2.5 tons)
1990 to 2011, or well-renovated older home22 – 2833,000 – 42,000 BTU/h (3 to 3.5 tons)
1960 to 1989, original insulation28 – 3542,000 – 52,000 BTU/h (3.5 to 4.5 tons)
Before 1960, plex or poorly insulated cottage35 – 4552,000 – 67,000 BTU/h (4.5 to 5.5 tons)

If the result for your home points to more than 5 tons, it is often cheaper to reduce the load first. Air sealing and attic insulation can bring the required size down by half a ton or more; see our attic insulation quotes page before you sign for a bigger unit.

Why a heat pump size calculator is only a first step

In Canada, the reference method for residential heat loss is the CSA F280 standard. A contractor using it measures each room, the walls, windows, ceiling insulation and air leakage, then applies the design temperature for your town. Natural Resources Canada publishes a free air-source heat pump sizing and selection toolkit that installers use to match that load to real equipment performance at low temperatures.

Getting this step right matters in both directions:

  • Oversized: the unit short-cycles in spring and fall, removes less humidity in summer, wears faster and costs more up front.
  • Undersized without a plan: the backup baseboards or electric elements run often in January, and your Hydro-Québec bill climbs more than expected.
  • Right-sized for the climate: the heat pump covers most of the winter, and a modest backup handles only the coldest hours.

Ducted or ductless: how size changes the choice

A central ducted heat pump replaces or works with a furnace and uses your existing ducts. It suits houses that already have ductwork in good condition and a load of roughly 2 to 5 tons. A ductless mini-split sends heat through one or more wall heads and is popular in Montreal plexes, condos and homes heated with baseboards, where there are no ducts.

With ductless systems, total tons are not enough: each closed room needs its own airflow. A single head in the living room can carry an open main floor, but bedrooms behind closed doors usually stay on baseboards unless you add heads. Our ductless mini-split quotes page explains the common layouts.

Heat pump cost by size in 2026

The ranges below are indicative installed prices observed in the Quebec market in 2026, before taxes and before rebates. They are not official prices; each contractor sets its own rates depending on equipment brand, electrical work and access.

SystemTypical sizeIndicative installed price
Ductless mini-split, 1 head0.75 – 1.5 tons$3,500 – $6,000
Ductless multi-zone, 2 to 4 heads2 – 3.5 tons$7,500 – $17,000
Central ducted, existing ducts2 – 3 tons$9,000 – $15,000
Central ducted, cold-climate, larger home3.5 – 5 tons$12,000 – $20,000

For a detailed price breakdown, including electrical panel upgrades and line-set lengths, read our heat pump installation cost guide for Quebec. Rebates can cut the final bill significantly: the conditions for Hydro-Québec’s LogisVert program are explained in our LogisVert heat pump rebate article.

Checklist before you request heat pump quotes

  1. Note your heated floor area, including any finished basement.
  2. Gather your last 12 months of electricity or fuel bills; they reveal how much heat the house really uses.
  3. Check the condition of your ducts, or list the rooms that would need a ductless head.
  4. Look at your electrical panel: older 100 A panels sometimes need an upgrade.
  5. Ask each contractor for a written room-by-room load calculation, the model number and its rated capacity at -15 °C and -25 °C.
  6. Confirm the contractor holds a valid Régie du bâtiment du Québec licence (verifiable on rbq.gouv.qc.ca) and that refrigerant work is done by certified technicians.
  7. Compare at least three quotes on the same size and backup strategy, not just the price.

Compare up to 4 heat pump installers

One short form, free quotes from licensed contractors in your area.

Get heat pump quotes →

Frequently Asked Questions

What size heat pump do I need for a 2,000 sq ft house?

In the Montreal area, a 2,000 sq ft house built in the 1990s or 2000s typically has a design heating load of roughly 45,000 to 55,000 BTU/h, which points to about 4 tons for a heat pump meant to cover most of the heating. A recent, airtight house of the same size may need only 2.5 to 3.5 tons. Only a proper load calculation can confirm it.

How many BTU per square foot for a heat pump in Canada?

For heating in a cold Canadian climate, planning figures range from about 15 BTU/h per square foot for new high-performance homes to 40 or more for older, poorly insulated houses. Cooling loads are lower, often 15 to 20 BTU/h per square foot, which is why sizing for cooling alone gives a smaller unit.

Is it better to oversize or undersize a heat pump?

Neither is ideal. A slightly undersized cold-climate unit with planned backup heat is usually more efficient and comfortable than an oversized unit that short-cycles. A grossly undersized unit, however, leaves the backup doing much of the work in winter.

Can a heat pump heat my whole house in a Quebec winter?

A well-sized cold-climate heat pump can cover most of the heating season in southern Quebec, but most installations keep a backup source, such as baseboards, an electric furnace element or an existing furnace, for the coldest nights.

How many tons is a 36,000 BTU heat pump?

A 36,000 BTU/h heat pump is a 3-ton unit, since one ton equals 12,000 BTU/h. Remember that this nominal rating is measured in mild weather; check the capacity the manufacturer lists at -15 °C and -25 °C.